Coil Pressure

HVAC Coil Specifications & Refrigerant Compatibility


1. Evaporator & Condenser Coil Specifications

Key design parameters for optimal performance:

Parameter Evaporator Coil Condenser Coil Industry Standard
Material Copper tubing, aluminum fins Copper/aluminum or microchannel Copper wall thickness: ≥0.032″
Fin Density 12–18 fins/inch 10–16 fins/inch Higher density = better heat transfer
Surface Area 500–1,200 in²/ton 400–800 in²/ton Varies by SEER rating
Operating Pressure 120–150 PSI (R-410A) 300–450 PSI (R-410A) R-32 systems: +20% pressure
Row Depth 1–3 rows 1 row (microchannel) or 1–2 rows 2-row standard for efficiency
Airflow (CFM/Ton) 350–450 CFM N/A Critical for dehumidification
Refrigerant Charge 2–6 lbs/ton 3–8 lbs/ton Depends on line set length

2. Refrigerant Compatibility Chart

Always match coils to refrigerant type!

Refrigerant Global Warming Potential (GWP) Compatible Coil Materials Max Operating Pressure Notes
R-22 1,810 Copper/aluminum 300 PSI Phased out; retrofit only
R-410A 2,088 Copper/aluminum (thick-wall) 600 PSI Standard for 2009–2020 systems
R-32 675 Microchannel or thick copper 650 PSI Requires flare fittings; low GWP
R-454B 467 Microchannel/aluminum 600 PSI R-410A replacement; lower GWP
R-290 (Propane) 3 Standard coils 350 PSI Flammable; charge ≤150g per circuit
R-1234yf <1 Aluminum/microchannel 500 PSI Emerging; ultra-low GWP

Critical Compatibility Rules:

  • R-410A/R-32 Systems: Require thicker-walled coils (≥0.032″) vs. R-22 (0.028″).
  • Microchannel Coils: Compatible with R-410A, R-32, R-454B (not R-22).
  • Oil Compatibility:
    • R-22 uses mineral oil.
    • R-410A/R-32 use POE oil – never mix oils!

3. Retrofit Compatibility

Upgrading refrigerants? Follow these guidelines:

Original Refrigerant New Refrigerant Coil Action Required
R-22 R-410A Replace coil (R-410A pressure too high)
R-410A R-32 Compatible if POE oil used; may need TXV swap
R-410A R-454B Drop-in compatible (similar pressure)
R-22 R-290 Flush mineral oil; add POE oil

4. Coil Selection Guide by System Type

System Type Ideal Coil Refrigerant Pairing Efficiency Impact
Standard AC 2-row copper/aluminum R-410A 14–18 SEER
High-Efficiency AC Microchannel R-32 20–26 SEER
Heat Pump Corrosion-resistant coating R-454B 9–12 HSPF
Retrofit Thick-wall copper R-290 Limited to small systems

5. Maintenance Impact on Compatibility

  • Dirty Coils:
    • Reduce heat transfer by 20–30%.
    • Cause refrigerant overcharge symptoms (high pressure).
  • Corrosion:
    • Formicary corrosion (copper): Caused by volatile organic compounds (VOCs).
    • Prevent with coil coatings (e.g., epoxy, hydrophilic).

6. Troubleshooting Mismatches

Symptom Possible Mismatch Solution
High Head Pressure R-410A in R-22 coil Replace condenser coil
Frequent Leaks Microchannel coil with R-22 Retrofit to R-454B
Poor Cooling Wrong TXV for refrigerant Calibrate TXV for new gas
Oil Sludge Mineral + POE oil mixed Flush system; replace oil

Summary

  • Coils must match refrigerant pressure/temperature profiles.
  • R-410A → R-32/R-454B transitions are viable with proper coil prep.
  • Microchannel coils optimize efficiency with low-GWP refrigerants.

⚠️ Warning: Never retrofit a system without verifying coil pressure ratings!